In order to pass LSI certification L50-501 exam, selecting the appropriate training tools is very necessary. And professional study materials about LSI certification L50-501 exam is a very important part. Our ITCertKing can have a good and quick provide of professional study materials about LSI certification L50-501 exam. Our ITCertKing IT experts are very experienced and their study materials are very close to the actual exam questions, almost the same. ITCertKing is a convenient website specifically for people who want to take the certification exams, which can effectively help the candidates to pass the exam.
ITCertKing is a professional IT certification sites, the certification success rate is 100%. This number is proved by candidates through practice. Because ITCertKing has a strong IT team of experts, they are committed to study exam questions and answers, and serve the vital interests of the majority of candidates. They use their own professional mind and experience to meet the needs of the candidates. According to the needs of the candidate, they consider the issue from all angles, and manufacturing applicability exam training materials. This material is LSI L50-501 exam training materials, which including questions and answers.
Exam Code: L50-501
Exam Name: LSI (LSI SVM5 Implementation Engineer)
One year free update, No help, Full refund!
Total Q&A: 119 Questions and Answers
Last Update: 2013-09-15
LSI L50-501 is one of the important certification exams. ITCertKing's experienced IT experts through their extensive experience and professional IT expertise have come up with IT certification exam study materials to help people pass LSI Certification L50-501 exam successfully. ITCertKing's providing learning materials can not only help you 100% pass the exam, but also provide you a free one-year update service.
The LSI L50-501 certification exam is not only validate your skills but also prove your expertise. It can prove to your boss that he did not hire you in vain. The current IT industry needs a reliable source of LSI L50-501 certification exam, ITCertKing is a good choice. Select ITCertKing L50-501 exam material, so that you do not need yo waste your money and effort. And it will also allow you to have a better future.
The appropriate selection of training is a guarantee of success. However, the choice is very important, ITCertKing popularity is well known, there is no reason not to choose it. Of course, Give you the the perfect training materials, if you do not fit this information that is still not effective. So before using ITCertKing training materials, you can download some free questions and answers as a trial, so that you can do the most authentic exam preparation. This is why thousands of candidates depends ITCertKing one of the important reason. We provide the best and most affordable, most complete exam training materials to help them pass the exam.
L50-501 Free Demo Download: http://www.itcertking.com/L50-501_exam.html
NO.1 A customer wants to create a SVM stripe. Which SVM stripe value should be set?
A. 64 KB
B. 256 KB
C. 512 KB
D. 1 MB
Answer: D
LSI L50-501 L50-501 L50-501
NO.2 At the end of the SVM installation, which three actions should you perform to ensure that the installation
is correct.? (Choose three.)
A. Test failover between two SVMs to make sure that you can successfully failover between SVMs.
B. Make sure that the SVM recognizes the DPM and that the DPM recognizes all of the devices that are
connected to the DPM ports.
C. Make sure that the SVM and DPM recognize the LUNs available on the storage array.
D. Make sure that the DPMs can communicate with each other.
E. Make sure that the LSI Failover Driver is installed on the SVM server.
Answer: A,B,C
LSI test L50-501 dumps L50-501 L50-501 exam dumps
NO.3 Your current SAN environment includes a storage system with LUNs exposed directly to Windows hosts.
You have been asked to integrate this storage system into the new SVM domain. Which statement is
correct?
A. The existing data can be moved to an SVM virtual volume while the application is still writing to the
source LUN.
B. The physical LUN containing the data must be unmounted from the host while the data is been moved
to an SVM virtual volume.
C. The physical LUN containing the data must be mounted to the host while the data is been moved to an
SVM virtual volume.
D. The physical LUN containing the data must be mounted to the SVM servers while the data is been
moved to an SVM virtual volume.
Answer: B
LSI L50-501 L50-501 questions L50-501
NO.4 Where is the SVM metadata stored?
A. On a mirror, between the two SVM internal hard drives.
B. On a mirror, between the managed storage array LUNs and the SVM internal hard drive.
C. On a mirror, between managed storage array LUNs.
D. On a mirror, between the two SVM internal hard drive partitions.
Answer: C
LSI demo L50-501 test answers L50-501 exam prep L50-501 exam dumps
NO.5 Two SVM servers in SVM Domain A are connected over Fibre Channel with two SVM servers in SVM
Domain B. The SVM servers' HBA at each domain can see the SVM servers' HBA at the other SVM
domain. What should you do to interconnect the SVM domains?
A. An SVM automatically negotiates the connection with the SVMs in other domains over Fibre Channel.
B. SVM domains should not be interconnected.
C. To interconnect two SVM domains, select Tools > Options > General > Configuration > Connect SVM
Domain.
D. To interconnect two SVM domains, select Tools > Options > General > Configuration > Connect FC
Domain.
Answer: A
LSI test questions L50-501 test questions L50-501 test answers L50-501
NO.6 A customer is running a cluster with cluster nodes and storage on either site and requires synchronous
mirroring across the two sites. You proposed a stretched SVM domain and now you need to configure the
zoning. Which two zoning rules apply to this configuration? (Choose two.)
A. Each DPM must see both storage systems.
B. Each DPM must only see the local storage system.
C. Each cluster node must see both SVM servers.
D. The SVM servers must see each other.
Answer: A,D
LSI L50-501 exam prep L50-501 study guide L50-501 answers real questions L50-501 exam dumps L50-501 exam dumps
NO.7 Which statement about the SVM server software upgrade is true?
A. The SVM server must be rebooted as part of the software upgrade process.
B. The SVM server must only be rebooted on major versions, e.g 5.1 to 5.2.
C. The SVM server can stay online during the software upgrade.
D. The DPMs must be taken offline during the SVM server reboot.
Answer: A
LSI certification L50-501 study guide L50-501 L50-501 test
NO.8 What are two requirements to set up a stretched SVM domain across two datacenters on the same
campus? (Choose two.)
A. Both SVM servers must be located on the same site.
B. The sites must be interconnected through two fabrics/ISLs.
C. Each site must have a minimum of one copy of the setup volume.
D. A dedicated IP link must be provided to interconnect the SVM servers.
Answer: B,C
LSI certification L50-501 L50-501 test
NO.9 During the SVM Management software installation, which two adapters would you select to be
controlled by the SVM? (Choose two.)
A. Emulex Fibre Channel adapter
B. Qlogic Fibre Channel adapter
C. Microsoft iSCSI initiator
D. Smart Array controller
Answer: B,C
LSI L50-501 L50-501 L50-501
NO.10 You have a customer that feels that their application can take advantage of striping their data. Which
two conditions will improve performance? (Choose two.)
A. Striping across two different storage systems.
B. Servers are running a transactional application where I/Os per second are required.
C. Disks that are available for inclusion in the stripe set are not of equal size.
D. Disks that are available for inclusion in the stripe set are of equal size.
Answer: A,D
LSI demo L50-501 L50-501 L50-501
NO.11 What should you do before starting the SVM server software upgrade process?
A. Reboot the SVM server.
B. Disconnect the SVM Fibre Channel cables.
C. Shut down the SVM Web server.
D. Uninstall the SVM server agent.
Answer: B
LSI exam dumps L50-501 L50-501
NO.12 Which parameter must be the same for SVM servers that manage the same SVM domain?
A. serial number
B. SVM domain name
C. computer name
D. WWNN
Answer: B
LSI practice test L50-501 certification L50-501 L50-501
NO.13 When adding storage to an existing SVM pool, what must be considered?
A. Growing the LUN will provide better utilization of storage.
B. Always pay attention to the performance characteristics of the storage.
C. Always select storage with different storage characteristics.
D. Adding storage to an existing pool will reduce performance.
Answer: B
LSI demo L50-501 L50-501
NO.14 Which statement describes what should be performed after a DPM image upgrade?
A. The DPM rank must be modified.
B. Set the DPM maximum frame size.
C. The DPM image upgrade does not change the DPM configuration parameters.
D. Configure the DPM ports type and speed.
Answer: C
LSI test answers L50-501 L50-501 test questions L50-501 L50-501 L50-501 test answers
NO.15 What is the difference between the active SVM server and the passive SVM server?
A. The passive SVM server takes control when the active SVM server is too busy.
B. The passive SVM server is a standby server only and does not perform any management tasks.
C. The passive SVM server can only modify objects but cannot create objects.
D. The passive SVM server can only manage user accounts.
Answer: B
LSI L50-501 L50-501 answers real questions L50-501
ITCertKing offer the latest MB6-886 exam material and high-quality 74-343 pdf questions & answers. Our 70-342 VCE testing engine and 642-980 study guide can help you pass the real exam. High-quality 9L0-620 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertking.com/L50-501_exam.html
没有评论:
发表评论